It is used in combination with a gas chromatograph
A headspace sampler is a sample pretreatment device for gas chromatographic analysis. Compared with other sample pretreatment methods such as solvent extraction and thermal desorption, it has the advantages of being simpler and more practical, having higher working efficiency, and better reproducibility of chromatographic analysis results. It is one of the preferred methods for gas chromatographic quantitative analysis.
1.With a full Chinese liquid crystal display, it is simple to operate and can be started with one key. It can automatically perform heating and balancing, needle insertion, sampling, injection, start the chromatograph and workstation, replace the sample bottle, etc., achieving full automation of the process.
2.It can preset 20 samples without the need for manual intervention, improving the reliability and consistency of the analytical work.
3.It has multiple fault judgment and processing modes, can automatically determine the position of the sample bottle, and can automatically avoid the position where no bottle is installed. In case of a position fault, it can prevent bottle collision. When there is an abnormal mechanical movement, it can automatically stop and give a prompt, effectively ensuring the reliability of high-precision movement and avoiding damage.
4.All sample transmission pipelines and quantitative loops are made of imported highly inert deactivated pipelines, with no residue and no cross-contamination, ensuring the repeatability and accuracy of sample injection.
5.The combination of the six-port valve and the quantitative loop minimizes the gas volume, ensuring the injection precision.
6.The connection point between the six-port valve and the transmission pipeline is located inside the heating and heat preservation chamber, with no cold spots during transmission, ensuring the integrity of the sample.
7.Adopting the classic positive pressure sampling method, it can measure liquid or solid samples, with high detection sensitivity. It performs injection under normal pressure, and the baseline does not drift.
8.All actions are driven by a motor, without the need for an external driving gas, which is safe and convenient to use.
9.The whole machine adopts an all-aluminum alloy structure, and a plastic shell is used at the same time, which ensures rigidity and greatly reduces the weight, ensuring transportation safety.
10.It has strong compatibility, can be easily connected to various gas chromatographs at home and abroad, and can start the chromatograph and workstation synchronously. It can also read the ready signal of the chromatograph and work in coordination with the chromatograph.
11.According to the needs of customers, six-port valves with different working temperatures and imported inert sampling needles can be optionally configured.
12.An electronic pressure control (EPC) system can be installed to reduce manual adjustment errors.
13.It is equipped with an RS232 interface, can communicate with the workstation, and various parameters can be set on the workstation.
Item
|
Parameter
|
Equilibration time
|
0 - 100min
|
Sampling time
|
0 - 10min
|
Injection time
|
0 - 10min
|
Purge time
|
0 - 10min
|
Pressurization time
|
0 - 10min
|
Quantitative loop equilibration time
|
0 - 10min
|
Analysis time
|
0 - 10min
|
Volume of quantitative tube
|
1ml (can be customized to 3ml)
|
Headspace vial specifications
|
10ml or 20ml
|
Sample positions
|
20 positions
|
Samples that can be heated cyclically
|
20 positions
|
RSD
|
1.5% (100ppm ethanol aqueous solution)
|
Power consumption
|
Peak value 1000W
|
Sample heating range
|
40°C - 200°C, temperature control accuracy 1°C (can be configured up to 250°C according to customer requirements)
|
Sample transfer tube heating range
|
40°C - 200°C, temperature control accuracy 1°C (can be configured up to 330°C according to customer requirements)
|
Injection valve heating range
|
40°C - 200°C, temperature control accuracy 1°C (can be configured up to 330°C according to customer requirements)
|
Dimensions
|
320mm×480mm×700mm
|
Instrument Configuration
One main unit, one box of headspace vials, and one pack of aluminum caps with rubber stoppers
User Provided
Nitrogen (purity 99.999%),pressure reducing valve
Deliver,Shipping And Serving
Provide product technical parameters, application scenarios, and other information to help you to choose the right equipment. Solution Design, sample testing, on-site visits is also supported.
Clarify details such as price, delivery time, payment methods, sign the contracts, and provide operation/ maintenance training to ensure customers use the instruments correctly.Assist customers with acceptance procedures and debugging each goods before shipment to ensure the instruments meet contract requirements.
In addition to the 1-year warranty, we also provide lifelong remote technical support to solve usage problems, provide regular maintenance services, and solve specific problems for customers in a timely manner.